A new AC, an electric geyser or a built-in oven usually comes with the same instruction from the electrician: “Is ke liye alag line dalni paregi.” That separate line is almost always 4 mm² wire, also known as 7/36. It is the size that lets one heavy appliance run at full power without heating the wiring or tripping the breaker.
This guide explains which appliances 4 mm² wire can safely run, which ones need a bigger or smaller size, and how to wire a dedicated appliance line correctly.
4 mm² (7/36) Wire at a Glance
| Detail | 4 mm² (7/36) wire |
|---|---|
| Construction | 7 strands, each 0.036 inch thick |
| Cross-section | About 4.6 mm² (the 4 mm² class) |
| Typical current (in conduit) | Roughly 30 to 32 A |
| Common breaker | 20 A to 25 A, sometimes 32 A (as advised) |
| Rough load at 230 V | Up to about 6 to 7 kW |
| Main use | Dedicated lines for heavy appliances |
Why Heavy Appliances Need Their Own 4 mm² Line
Ordinary socket circuits are wired in 2.5 mm² or 7/29 and shared by many sockets. That works for a TV, a laptop charger or a fan. A heavy appliance, however, draws a large current for hours, and an AC compressor pulls an extra surge every time it starts.
Putting that load on a shared socket circuit overheats the socket, the plug and the wire. A dedicated 4 mm² line from the DB, with its own breaker, carries the current comfortably and keeps the rest of the house unaffected.
Appliances 4 mm² Wire Can Safely Run
| Appliance | Typical power | Is 4 mm² suitable? |
|---|---|---|
| 1 ton AC | About 1 to 1.3 kW | Yes, more than enough |
| 1.5 ton AC | About 1.5 to 2 kW | Yes, the standard choice |
| 2 ton AC | About 2 to 2.8 kW | Yes, on normal run lengths |
| Electric geyser | About 2 to 3 kW | Yes |
| Built-in electric oven | About 2 to 3.5 kW | Yes |
| Room heater | About 1.5 to 2 kW | Yes |
| Water pump (1 to 1.5 HP) | About 0.75 to 1.1 kW | Yes, handles the starting surge well |
These are typical figures. Always check the rating plate of your appliance, and ask your electrician to confirm the wire and breaker.
When 4 mm² Is Not Enough
- Very long runs. If the AC outdoor unit or pump is far from the DB, voltage drop increases. Move up to 7/44 (6 mm²).
- Several heavy appliances on one line. Two ACs or an oven and a geyser together should not share one 4 mm² line. Give each its own circuit, or use 7/44 as a sub-main to a small board.
- Instant electric water heaters. Some draw 5 kW or more. Check the manual; they may need 6 mm².
- Main line. 4 mm² is not a main line wire. Use 7/52 or 7/64 for that.
When 4 mm² Is More Than You Need
- Lights and fans need only 1 mm² or 3/29.
- Normal sockets for TV, fridge, washing machine and charging need 2.5 mm² or 7/29.
How to Wire a Dedicated 4 mm² Appliance Line
- Start from the DB. Give the appliance its own breaker in the distribution board.
- Run phase, neutral and earth. Use 4 mm² for phase and neutral, and an earth wire as your electrician advises. Red, black and green make the line easy to identify.
- Use a heavy-duty socket or isolator. A 15 A or 20 A socket, or a double pole isolator near the AC, is better than a normal 5 A socket.
- Keep joints to a minimum. Run the wire in one piece from the DB to the appliance wherever possible.
- Tighten every terminal. Loose terminals on heavy circuits are the most common cause of burnt sockets.
For AC-specific sizing by ton, see our AC wire size guide.
Why Choose Thrive Cables 4 mm² Wire
Thrive Cables makes 4 mm² (7/36) single core copper wire in Lahore with 99.9% pure copper and fire-retardant PVC insulation. Every coil has the full 7 strands at the right thickness, and it comes in 45 m and 90 m coils in 7 colours. Order at factory price on WhatsApp at +92 324 6570645.
Frequently Asked Questions About 4 mm² Wire
Is 4 mm² the same as 7/36 wire?
Yes. 7/36 has about 4.6 mm² of copper and is used as the 4 mm² class of wire in Pakistan.
How many amps can 4 mm² wire carry?
Roughly 30 to 32 A in conduit, depending on installation. Appliance circuits are usually protected by a 20 A to 25 A breaker.
Can I run two ACs on one 4 mm² line?
It is not recommended. Give each AC its own line and breaker so a fault on one does not affect the other.
Is 4 mm² enough for an electric geyser?
For most 2 to 3 kW geysers, yes. Instant heaters of 5 kW or more may need 6 mm².
Do I need 4 mm² for the fridge?
No. A fridge uses little power and works well on a normal 2.5 mm² socket circuit.
Conclusion
4 mm² (7/36) wire is the right size for one heavy appliance on its own line: an AC up to 2 ton, a geyser, an oven, a heater or a water pump. It carries roughly 30 A, handles starting surges and keeps the rest of the wiring cool. Use a bigger size for long runs or combined loads, a smaller one for lights and ordinary sockets, and have a qualified electrician confirm every heavy circuit.